Honeywell C7089U1006 Outdoor Temperature Sensor

May 22, 2015 - Comment

Outdoor Temperature Sensor senses outdoor temperature for the VisionPRO and VisionPRO IAQ and also can be used for dual fuel balance point temperature operation in heat pump applications.Convenience feature for homeowners.Mounting clip allows easy sensor positioning on siding or soffit. Includes 60 in. leadwires. Factory calibrated. No field calibration required. Maximum wire run of 200

Buy Now! $21.91Amazon.com Price
(as of April 19, 2020 8:16 am EDT - Details)

Outdoor Temperature Sensor senses outdoor temperature for the VisionPRO and VisionPRO IAQ and also can be used for dual fuel balance point temperature operation in heat pump applications.Convenience feature for homeowners.Mounting clip allows easy sensor positioning on siding or soffit. Includes 60 in. leadwires. Factory calibrated. No field calibration required. Maximum wire run of 200 feet. Product Specifications Description Outdoor sensor used to measure outdoor temperature. Application Sensor for VisionPRO Thermostats. Dimensions (in.) 2 1/4 in. x 3/8 in. with 60 in. leadwires. Dimensions (mm) 57 mm x 10 mm with 1524 mm leadwires. Mounting Mounting Clip provided and screws provided. Operating Humidity Range ( RH) 5 to 95 RH, noncondensing Temperature Range, Ambient (F) 40 F to +120 F. Temperature Range, Ambient (C) 40 C to +49 C. Used With VisionPRO+ Series Thermostats.

Product Features

  • Mounting clip allows easy sensor positioning on siding or soffit
  • Includes 60 in. leadwires
  • Factory calibrated; no field calibration required
  • Maximum wire run of 200 feet
  • 2 1/4 in. x 3/8 in. with 60 in. leadwires

Comments

Patriarchal Unit says:

Web page Technical error Be careful when ordering this Item. I was shopping for a programmable thermostat when I ran across this item. I thought it would be great to see the outside temperature displayed when checking my thermostat. I purchased a Honeywell RTH8500D thermostat to use with this sensor. The thermostat was on sale and the Amazon web page for the sensor indicated it would work with the thermostat. I copied and pasted part of the technical details from the web page for the sensor below: 

FL Z-Man 777 "Bass Man" says:

Temp Sensor Review Really appreciate the chart with the resistance/temp values. Leads are too short, though, and will not fit into the S1/S2 terminal blocks on the Honeywell 8000 series thermostats without stripping away some of the strands to make the conductor pack thinner. Overall, though a quality product.

Jeremy Furzer says:

Concerned about the Calibration I checked resistance out of the box against reference temperatures and calibration was off by 1-3 deg. C. The error is not linear, below -20C it reads 1-2 deg C colder and above zero it is reading 1-2 deg warmer. It not cost effective to return it because the refund of canadian inport duty and taxes is a hassel.